Operation
Operating manual 100-69 version 00.0 - 05/2013
31
5.4.2 Changing the needles
Fig. 14: Changing the needles
1. Swing the folding station aside, chapter 5.2.
The needles are freely accessible.
2. Loosen screw (2) and remove the needle from the needle holder (1).
3. Push the new needle into the drill-hole of the needle holder (1) as far
as it will go.
Seen from the operator’s side the scarf (4) of the left needle must point
to the left and the scarf (5) of the right needle must point to the right (see
sketch).
4. Tighten screw (2).
Risk of injuries from cuts and stitches!
Turn the main switch off.
Change the needles only with the main switch
switched off.
Do not reach into the area of the centre knife (3)
when changing the needles.
WARNING
Material damage!
After changing to another needle size the needle protection on the
hook has to be readjusted, Service Instructions.
ATTENTION
(1) - Needle holder
(2) - Screw
(3) - Center knife
(4) - Needle scarf left needle
(5) - Needle scarf right needle
ཱིི