Page view 69
Set-up
Operating manual 100-69 version 00.0 - 05/2013
68
3. Check the configuration of the connections at the switch element and
change the connections according to the existing mains voltage
(see wiring diagram).
4. Attach the cover again and fasten the screw.
5. Connect the mains plug.
6.4.4 Checking the nominal voltage of the vacuum device
The adaptation to the local mains voltage has to be done at the terminal
strip in control box (1). This adaptation may only be carried out by qualified
electricians.
Fig. 56: Nominal voltage vacuum device
1. Screw off the cover of the safety switch (1).
2. Check the arrangement of the connections to the safety switch and if
necessary, change the connections. (see wiring diagram)
3. If necessary, change the connections according to the local mains volt-
age.
4. Screw on the safety switch cover (1) again.
6.4.5 Direction of rotation of the sewing motor and the vacuum
blower
The sewing unit is equipped with the latest step motor technology. A check
of the direction of rotation of the sewing motor is not required because it is
automatically set by the control.
The direction of rotation of the vacuum blower can be inverted by
exchanging the phase (plug).
(1) - Cover of safety switch