Set-up
Operating manual 100-69 version 00.0 - 05/2013
69
6.5 Pneumatic connection
For the operation of the pneumatic components the sewing unit has to be
provided with anhydrous compressed air.
In case of a important air pressure decrease:
Increase the compressor output.
Increase the diameter of the compressed air hose.
Fig. 57: Pneumatic connection
Connecting the compressed air maintenance unit
Connect the connection hose (1) to the slide valve (2) and the com-
pressed air line by means of a hose coupling ¼ “.
Material damage!
For a trouble-free function of the pneumatic control processes the
compressed air net has to be rated as follows:
Even at the moment of the highest air consumption, the minimum
operating pressure must not drop below 6 bar .
ATTENTION
཰ཱ
(1) - Connection hose
(2) - Slide valve
(3) - Pressure gauge
(4) - Turning handle